1.Products with diaphragm edge, there may be injury, it is recommended to wear thick gloves when installing.
2.Please install the coupling guard and other peripheral devices to ensure safety.
3.Installation axis deviation exceeds allowable value, the coupling may deform causing damage or shorten the life.
4.Coupling allowable axial deviation including radial, angular and axial deviation. Installation, make adjustments to ensure that the axis deviation in the corresponding product directory under the permissible value range.
5.When multiple deviations occur simultaneously, the corresponding allowable value should be halved.
6.Order to extend the service life of the coupling, it is recommended to set the allowable axial offset of 1/3 or less.
7.Mounting shaft is inserted before tightening the screws, otherwise it will cause deform the coupling. Tighten the screws, use a torque wrench, do not use attachments other than the screws.
8.During operation if abnormal sounds, immediately stop operation, and installation accuracy, loose screws, etc. were examined. Recommends the screw after installation adhesive topcoat appearance and increase protection.
Installation and removal
1.The mounting shaft surface dust wipe clean dirty, wipe a thin layer of oil peers or lubricants.
2.Lingsi the coupling hole cleaner will clean, wipe the oil or lubricant.
3.Insert the Lingsi mounting shaft couplings; such as aperture is tight, taking care to avoid hitting with a hammer or hard metal installation.
4.Positioning is complete, press the diagonal direction, with the torque wrench (tightening torque specified 1/4) Gently tighten the screws.
5.Intensify (specified tightening torque 1/2) Repeat step 4 to complete action.
6.Press the specified tightening torques Tightening torques fasten.
7.Finally, press the circumferential direction successively tighten the screws.
8.When removing the device completely stopped under the state; sequentially loosen the lock screw.
![]() |
| Fluid Couplings |
Maintenance
1.The installation should be cleaned two shaft end, check the mouth, such as face keyway with the situation;
2.Diaphragm couplings installed, the normal operation of a class, you must check all the screws, if found loose, must be tightened, so that repeated several classes to ensure that no loose;
3.The diaphragm at high speed in order to prevent fretting wear occurs, leading to micro-cracking diaphragm bolt holes and damage, can be applied between the diaphragm with a solid lubricant such as molybdenum disulfide or antifriction coating film surface layer processing;
4.Diaphragm couplings should avoid long-term use and operation of overloading the accident;
5.Diaphragm coupling operation at work, you should always check whether a diaphragm coupling anomalies, anomalies occur if necessary and enter maintenance;
6.Diaphragm coupling may be due to the operation of the diaphragm couplings and equipment accidents cause personal in all venues must take appropriate safety precautions.
Chinabase Machinery is a group of manufacturing facilities, offering one-stop solution for mechanical power transmission products in China. We can supply a full-range of power transmissions products, such as chains,engineering chain, sprockets and plate wheels, pulleys, gearboxes, motors, couplings, gears and racks. Our product range also covers locking assemblies (clamping elements/locking device), taper bushes,Transmission Chain, QD bushes, bolt-on hubs, torque limiters, shaft collars, motor bases and motor slides, chain detachers, chain guides, universal joint,Linear Bearing, rod ends and yokes. Our products are used in many different industry sector, like in automation engineering, drive engineering,Cross Roller Guideway, conveyor technology, assembly and handling technology, packaging industries, the beverage, food and medical engineering, pharmaceutical production, and laboratory equipment.